Metrec•X CTD Tu UV

From: $10,780.00

Deploy this high performance, multiparameter sonde in-situ for weeks, months, or years.

Expand monitoring timelines and collect higher quality data while reducing maintenance costs. By eliminating biofouling-induced drift, UV•Xchange™ allows sensors to perform to their full potential on in-situ instruments. A copper nickel alloy cage option (shown) is available for incidental biofouling protection.

Select Product Options

Select the product options in the dropdown boxes below to tailor this configuration to your specific needs. Once completed, you may add this configuration to your RFQ, which you can submit at any time.

Note: Select product options from left to right/top to bottom for a more streamlined experience.

Product Description

This multiparameter sonde has proven to perform long term in-situ. With UV•Xchange™ preventing fouling-induced drift, the sensors to perform to their full potential for the duration of the deployment.

CT•Xchange™ boasts extended ranges on both parameters (0 to 90 mS/cm for conductivity and -5 to 45°C for temperature), and conductivity stability of +/- 0.003 mS/cm/month.

Tu•Xchange™ automatically adjusts to the appropriate range while in operation. As a result, high accuracy is achieved over the entire 0-3000 NTU range.

 
 
Product Info

Metrec•X

Sensor Ports Up to 5
Optional Remote Sensor Ports 4
Depth Rating 500 m, 6000 m
Housing Material 500 m: Acetal
Sensor Cage Material 500 m: Copper (optional upgrade)
Shackle Included
Communications RS-232, RS-485
Baud Rate 19200, 9600, 38400
GPS No
Power Source External
Data Output Real-time Output
Input Voltage 10-36 V
Length 482 mm (19.0″)
Diameter 114 mm (4.5″)
Weight in Air 500 m: 3.3 kg (7.2 lbs), 6000 m: 5.2 kg (11.3 lbs)
Weight in Water 500 m: 1.2 kg (2.6 lbs), 6000 m: 3.1 kg (6.7 lbs)
Biofouling Control Optional Upgrade
 
 
Product Info

CT•Xchange™

P•Xchange™

Tu•Xchange™

Parameter Conductivity, Temperature Pressure Turbidity
Depth Rating 6000 m 50 m, 100 m, 200 m, 500 m, 1000 m, 2000 m, 4000 m, 5000 m, 6000 m 200 m, 300 m
Range C: 0-90 mS/cm ᵇ, T: -5-45 ⁰C ᶜ 0-50 dBar, 0-100 dBar, 0-200 dBar, 0-500 dBar, 0-1000 dBar, 0-2000 dBar, 0-4000 dBar, 0-5000 dBar, 0-6000 dBar 0-3000 NTU ᵈ
Response Time C: 25 ms ʰ, T: 100 ms 10 ms < 0.7 s
Accuracy (+/-) C: 0.01 mS/cm, T: 0.005 ⁰C 0.05% FS 2% of reading or 0.2 NTU
Precision (+/-) C: 0.003 mS/cm, T: 0.003 ⁰C 0.03% FS 0.5 % reading or 0.1 NTU
Stability C: 0.003 mS/cm/month ͤ - -
Wiper - - 200 m: yes, 300 m: no
Length 109 mm (4.25″) 73 mm (2.86″) 200 m: 143 mm (5.61″), 300 m: 133 mm (5.25″)
Diameter 63 mm (2.47″) 11 mm (0.45″) 29 mm (1.13″)
Resolution C: 0.001 mS/cm, T: 0.001 ⁰C 0.02% FS 0.01 NTU
ᵃ Standard range
ᵇ Will over-range to 100 mS/cm. Inquire for specifications.
ᶜ Will over-range to 60 ⁰C. Inquire for specifications.
ᵈ Digital auto-ranging
ᵉ When deployed with UV•Xchange™
ᶠ For standard range only. 0.02 m/s for other ranges.
ᵍ For standard range only. 0.5-1.0 m/s for other ranges.
ʰ At 1 m/s flow