Micro•X Tu

$3,440.00$3,640.00

This real-time turbidity probe performs across the full NTU spectrum. 

Tu•Xchange automatically adjusts to the appropriate range while in operation. As a result, high accuracy is achieved over the entire 0-3000 NTU range. Designed for integration applications, Micro•X fits on ROVs and AUVs of nearly any size.

Select Product Options

Select the product options in the dropdown boxes below to tailor this configuration to your specific needs. Once completed, you may add this configuration to your RFQ, which you can submit at any time.

Note: Select product options from left to right/top to bottom for a more streamlined experience.

Product Description

Micro•X combines with Tu•Xchange to be a real-time auto-ranging turbidity probe. The diminutive instrument is ideal for installation on vehicles big and small.

Eliminating the need for multiple sensors to accommodate large variation in turbidity, Tu•Xchange automatically adjusts to the appropriate range while in operation. As a result, high accuracy is achieved over the entire 0-3000 NTU range. For long-term deployments in sediment rich areas, a wiper option is now available.

Tu•Xchange accuracy is quoted as a percentage of reading. A sensor measuring 900 NTU is accurate to +/-18 NTU, while measuring 500 NTU it is accurate to +/- 10 NTU, based on its +/- 2% specification. As the measurement nears 0 NTU the accuracy specification also includes a floor. For example, the same sensor measuring at or below 1 NTU would have an error of +/- 0.2 NTU.

 
 
Product Info

Micro•X

Sensor Ports 1
Depth Rating 500 m, 6000 m
Housing Material 500 m: Acetal, 6000 m: Titanium
Sensor Cage Material N/A
Other Applications AUV / Glider Integration, Buoy / In-Situ Deployments, ROV Integration
Shackle No
Communications RS-232, RS-485
Baud Rate 19200, 38400, 9600
GPS No
Power Source External
Data Output Real-time Output
Input Voltage 8-26 V
Length 214 mm (8.4″)
Diameter 33 mm (1.3″)
Weight in Air 500 m: 0.24 kg (052 lbs), 6000 m: 0.39 kg (0.86 lbs)
Weight in Water 500 m: 0.09 kg (0.2 lbs), 6000 m: 0.25 kg (0.55 lbs)
Biofouling Control No
 
 
Product Info

Tu•Xchange™

Parameter Turbidity
Depth Rating 200 m, 300 m
Range 0-3000 NTU ᵈ
Response Time < 0.7 s
Accuracy (+/-) 2% of reading or 0.2 NTU
Precision (+/-) 0.5 % reading or 0.1 NTU
Wiper 200 m: yes, 300 m: no
Length 200 m: 143 mm (5.61″), 300 m: 133 mm (5.25″)
Diameter 29 mm (1.13″)
Resolution 0.01 NTU
ᵃ Standard range
ᵇ Will over-range to 100 mS/cm. Inquire for specifications.
ᶜ Will over-range to 60 ⁰C. Inquire for specifications.
ᵈ Digital auto-ranging
ᵉ When deployed with UV•Xchange™
ᶠ For standard range only. 0.02 m/s for other ranges.
ᵍ For standard range only. 0.5-1.0 m/s for other ranges.
ʰ At 1 m/s flow
Instrument Manual

Sensor Manual

Software Manual

Data Sheets

You may also like…