Plus•X CTD Tu

From: $11,980.00

Need turbidity on your CTD? Look no further.

Add turbidity to Plus•X and still have room for more. Our largest logger accommodates up to five sensors on the endcap, with room for additional remote sensors. Auto-ranging Tu•Xchange™ automatically adjusts to the appropriate range while in operation, achieving high accuracy performance over the entire 0-3000 NTU range.

Select Product Options

Select the product options in the dropdown boxes below to tailor this configuration to your specific needs. Once completed, you may add this configuration to your RFQ, which you can submit at any time.

Note: Select product options from left to right/top to bottom for a more streamlined experience.

Product Description

Add turbidity to Plus•X and still have room for more. Our largest logger accommodates up to five sensors on the endcap, with room for additional remote sensors. Auto-ranging Tu•Xchange™ automatically adjusts to the appropriate range while in operation, achieving high accuracy performance over the entire 0-3000 NTU range. Learn about the benefits offered by the unique 4-electrode design of AML’s conductvity-temperature sensor, CT•Xchange™.

Available with Data•Xchange to enable WiFi communication, automatic data transfer, and integrated GPS positioning.

 
 
Product Info

Plus•X

Sensor Ports Up to 5
Optional Remote Sensor Ports 4
Depth Rating 500 m, 5000 m, 6000 m
Housing Material 500 m: Acetal, 5000 m: Anodized Aluminum 6061, 6000 m: Anodized Aluminum 7075
Sensor Cage Material 500 m: Acetal, 5000m: Anodized Aluminum, 6000m: Anodized Aluminum
Other Applications Buoy / In-Situ Deployments, Coastal Monitoring
Shackle Included
Communications RS-232, RS-485, WiFi (optional upgrade)
Baud Rate 19200, 9600, 38400
GPS Optional Upgrade
Power Source Internally Rechargeable Battery, External
Data Output Logs to Memory, Real-time Output
Input Voltage 8-26 V
Length 500 m: 860 mm (33.9″), 5000 m: 881 mm (34.9″), 6000 m: 881 mm (34.9″)
Diameter 100 mm (4.0″)
Weight in Air 500 m: 5.9 kg (13.0 lbs), 5000 m: 7.7 kg (17.0 lbs), 6000 m: 7.7 kg (17.0 lbs)
Weight in Water 500 m: 2.2 kg (4.9 lbs), 5000 m: 3.4 kg (7.5) lbs, 6000 m: 3.4 kg (7.5 lbs)
Biofouling Control Optional Upgrade
 
 
Product Info

CT•Xchange™

P•Xchange™

Tu•Xchange™

Parameter Conductivity, Temperature Pressure Turbidity
Depth Rating 6000 m 50 m, 100 m, 200 m, 500 m, 1000 m, 2000 m, 4000 m, 5000 m, 6000 m 200 m, 300 m
Range C: 0-90 mS/cm ᵇ, T: -5-45 ⁰C ᶜ 0-50 dBar, 0-100 dBar, 0-200 dBar, 0-500 dBar, 0-1000 dBar, 0-2000 dBar, 0-4000 dBar, 0-5000 dBar, 0-6000 dBar 0-3000 NTU ᵈ
Response Time C: 25 ms ʰ, T: 100 ms 10 ms < 0.7 s
Accuracy (+/-) C: 0.01 mS/cm, T: 0.005 ⁰C 0.05% FS 2% of reading or 0.2 NTU
Precision (+/-) C: 0.003 mS/cm, T: 0.003 ⁰C 0.03% FS 0.5 % reading or 0.1 NTU
Stability C: 0.003 mS/cm/month ͤ - -
Wiper - - 200 m: yes, 300 m: no
Length 109 mm (4.25″) 73 mm (2.86″) 200 m: 143 mm (5.61″), 300 m: 133 mm (5.25″)
Diameter 63 mm (2.47″) 11 mm (0.45″) 29 mm (1.13″)
Resolution C: 0.001 mS/cm, T: 0.001 ⁰C 0.02% FS 0.01 NTU
ᵃ Standard range
ᵇ Will over-range to 100 mS/cm. Inquire for specifications.
ᶜ Will over-range to 60 ⁰C. Inquire for specifications.
ᵈ Digital auto-ranging
ᵉ When deployed with UV•Xchange™
ᶠ For standard range only. 0.02 m/s for other ranges.
ᵍ For standard range only. 0.5-1.0 m/s for other ranges.
ʰ At 1 m/s flow