Plus•X SVPT

From: $11,180.00

This classic sound velocity profiler keeps up with technological advances.

Similar in size and appearance to the AML SV Plus workhorses of previous decades, Plus•X retains the reliability and robustness of its predecessors while offering hydrographers the latest sensor technology.

Select Product Options

Select the product options in the dropdown boxes below to tailor this configuration to your specific needs. You may also optionally add a temperature sensor (T•Xchange) to your SVP profiler. Once completed, you may add this configuration to your RFQ, which you can submit at any time.

Note: Select product options from left to right/top to bottom for a more streamlined experience.

Product Description

Plus•X is the latest generation of a long line of Plus profilers, making it a popular choice for longtime customers. Boasting the most space of any of our loggers, Plus•X accommodates up to five sensors on the endcap, with room for additional remote sensors.

Similar in size and appearance to the AML SV Plus workhorses of previous decades, Plus•X retains the reliability and robustness of its predecessors while offering hydrographers the latest sensor technology.

Take full advantage of Xchange™ sensors with Plus•X: Want to measure CTD and SV simultaneously? Add CT•Xchange™. Want to collect turbidity data during your profiles? Add Tu•Xchange™.

Available with Data•Xchange to enable WiFi communication, automatic data transfer, and integrated GPS positioning.

 

 
 
Product Info

Plus•X

Sensor Ports4 or 5
Optional Remote Sensor Ports4
Depth Rating500 m, 5000 m, 6000 m
Housing Material500 m: Acetal, 5000 m: Anodized Aluminum 6061, 6000 m: Anodized Aluminum 7075
Sensor Cage Material500 m: Acetal, 5000 m: Anodized Aluminum 6061, 6000 m: Anodized Aluminum 7075
Other ApplicationsBuoy / In-Situ Deployments, Coastal Monitoring
ShackleIncluded
CommunicationsRS-232, RS-485, WiFi (optional upgrade)
Baud Rate19200, 9600, 38400
GPSOptional Upgrade
Power SourceInternally Rechargeable Battery, External
Data OutputLogs to Memory, Real-time Output
Input Voltage8-26 V
Length500 m: 860 mm (33.9″), 5000 m: 881 mm (34.9″), 6000 m: 881 mm (34.9″)
Diameter100 mm (4.0″)
Weight in Air500 m: 5.9 kg (13.0 lbs), 5000 m: 7.7 kg (17.0 lbs), 6000 m: 7.7 kg (17.0 lbs)
Weight in Water500 m: 2.2 kg (4.9 lbs), 5000 m: 3.4 kg (7.5) lbs, 6000 m: 3.4 kg (7.5 lbs)
Biofouling ControlOptional Upgrade
 
 
Product Info

SV•Xchange™

P•Xchange™

T•Xchange™

ParameterSound VelocityPressureTemperature
Depth Rating6000 m50 m, 100 m, 200 m, 500 m, 1000 m, 2000 m, 4000 m, 5000 m, 6000 m6000 m
Range1375-1625 m/s ᵃ, 1100-2000 m/s, 500-2000 m/s0-50 dBar, 0-100 dBar, 0-200 dBar, 0-500 dBar, 0-1000 dBar, 0-2000 dBar, 0-4000 dBar, 0-5000 dBar, 0-6000 dBar-5-45 ⁰C ᶜ
Response Time20 ms, (sample duration 47 μs)10 ms100 ms
Accuracy (+/-)0.025 m/s ᵍ0.05% FS0.005 ⁰C
Precision (+/-)0.006 m/s ᶠ0.03% FS0.003 ⁰C
Length87 mm (3.44″)73 mm (2.86″)90 mm (3.53″)
Diameter32 mm (1.25″)11 mm (0.45″)23 mm (0.9″)
Resolution0.001 m/s0.02% FS0.001 ⁰C