Plus•X SVPT

From: $11,180.00

This classic sound velocity profiler keeps up with technological advances.

Similar in size and appearance to the AML SV Plus workhorses of previous decades, Plus•X retains the reliability and robustness of its predecessors while offering hydrographers the latest sensor technology.

Select Product Options

Select the product options in the dropdown boxes below to tailor this configuration to your specific needs. You may also optionally add a temperature sensor (T•Xchange) to your SVP profiler. Once completed, you may add this configuration to your RFQ, which you can submit at any time.

Note: Select product options from left to right/top to bottom for a more streamlined experience.

Product Description

Plus•X is the latest generation of a long line of Plus profilers, making it a popular choice for longtime customers. Boasting the most space of any of our loggers, Plus•X accommodates up to five sensors on the endcap, with room for additional remote sensors.

Similar in size and appearance to the AML SV Plus workhorses of previous decades, Plus•X retains the reliability and robustness of its predecessors while offering hydrographers the latest sensor technology.

Take full advantage of Xchange™ sensors with Plus•X: Want to measure CTD and SV simultaneously? Add CT•Xchange™. Want to collect turbidity data during your profiles? Add Tu•Xchange™.

Available with Data•Xchange to enable WiFi communication, automatic data transfer, and integrated GPS positioning.

 

 
 
Product Info

Plus•X

Sensor Ports Up to 5
Optional Remote Sensor Ports 4
Depth Rating 500 m, 5000 m, 6000 m
Housing Material 500 m: Acetal, 5000 m: Anodized Aluminum 6061, 6000 m: Anodized Aluminum 7075
Sensor Cage Material 500 m: Acetal, 5000m: Anodized Aluminum, 6000m: Anodized Aluminum
Other Applications Buoy / In-Situ Deployments, Coastal Monitoring
Shackle Included
Communications RS-232, RS-485, WiFi (optional upgrade)
Baud Rate 19200, 9600, 38400
GPS Optional Upgrade
Power Source Internally Rechargeable Battery, External
Data Output Logs to Memory, Real-time Output
Input Voltage 8-26 V
Length 500 m: 860 mm (33.9″), 5000 m: 881 mm (34.9″), 6000 m: 881 mm (34.9″)
Diameter 100 mm (4.0″)
Weight in Air 500 m: 5.9 kg (13.0 lbs), 5000 m: 7.7 kg (17.0 lbs), 6000 m: 7.7 kg (17.0 lbs)
Weight in Water 500 m: 2.2 kg (4.9 lbs), 5000 m: 3.4 kg (7.5) lbs, 6000 m: 3.4 kg (7.5 lbs)
Biofouling Control Optional Upgrade
 
 
Product Info

SV•Xchange™

P•Xchange™

T•Xchange™

Parameter Sound Velocity Pressure Temperature
Depth Rating 6000 m 50 m, 100 m, 200 m, 500 m, 1000 m, 2000 m, 4000 m, 5000 m, 6000 m 6000 m
Range 1375-1625 m/s ᵃ, 1100-2000 m/s, 500-2000 m/s 0-50 dBar, 0-100 dBar, 0-200 dBar, 0-500 dBar, 0-1000 dBar, 0-2000 dBar, 0-4000 dBar, 0-5000 dBar, 0-6000 dBar -5-45 ⁰C ᶜ
Response Time 20 ms, (sample duration 47 μs) 10 ms 100 ms
Accuracy (+/-) 0.025 m/s ᵍ 0.05% FS 0.005 ⁰C
Precision (+/-) 0.006 m/s ᶠ 0.03% FS 0.003 ⁰C
Length 87 mm (3.44″) 73 mm (2.86″) 90 mm (3.53″)
Diameter 32 mm (1.25″) 11 mm (0.45″) 23 mm (0.9″)
Resolution 0.001 m/s 0.02% FS 0.001 ⁰C
Instrument Manual

Sensor Manuals

Software Manual

You may also like…