Smart•X CTD UV

From: $6,485.00

Install UV•Xchange on Smart•X for a high performance in-situ CTD.

Smart•X is ideal for long term, in-situ deployments with UV•Xchange for biofouling control. By eliminating biofouling-induced drift, UV•Xchange allows sensors to perform to their full potential on in-situ instruments.

Select Product Options

Select the product options in the dropdown boxes below to tailor this configuration to your specific needs. Once completed, you may add this configuration to your RFQ, which you can submit at any time.

Note: Select product options from left to right/top to bottom for a more streamlined experience.

Product Description

Smart•X is ideal for long term, in-situ deployments with UV•Xchange™ for biofouling control. By eliminating biofouling-induced drift, UV•Xchange allows sensors to perform to their full potential on in-situ instruments. Install UV•Xchange on a Smart•X for a high performance in-situ CTD.

Why use AML’s biofouling control technology?

 
 
Product Info

Smart•X

Sensor Ports 3
Depth Rating 500 m, 6000 m
Housing Material 500 m: Acetal, 6000 m: Titanium
Sensor Cage Material 500 m: Carbon Fiber, 500 m: Copper (optional upgrade), 6000 m: Titanium
Shackle No
Communications RS-232, RS-485
GPS No
Power Source External
Data Output Real-time Output
Input Voltage 8-26 V
Length 419.5 mm (16.52″)
Diameter 69.9 mm (2.75″)
Weight in Air 500 m: 0.73 kg (1.6 lbs), 6000 m: 1.86 kg (4.1 lbs)
Weight in Water 500 m: 0.14 kg (0.3 lb), 6000 m: 1.27 kg (2.8 lbs)
Biofouling Control Optional Upgrade
 
 
Product Info

CT•Xchange™

P•Xchange™

Parameter Conductivity, Temperature Pressure
Depth Rating 6000 m 50 m, 100 m, 200 m, 500 m, 1000 m, 2000 m, 4000 m, 5000 m, 6000 m
Range C: 0-90 mS/cm ᵇ, T: -5-45 ⁰C ᶜ 0-50 dBar, 0-100 dBar, 0-200 dBar, 0-500 dBar, 0-1000 dBar, 0-2000 dBar, 0-4000 dBar, 0-5000 dBar, 0-6000 dBar
Response Time C: 25 ms ʰ, T: 100 ms 10 ms
Accuracy (+/-) C: 0.01 mS/cm, T: 0.005 ⁰C 0.05% FS
Precision (+/-) C: 0.003 mS/cm, T: 0.003 ⁰C 0.03% FS
Stability C: 0.003 mS/cm/month ͤ -
Length 109 mm (4.25″) 73 mm (2.86″)
Diameter 63 mm (2.47″) 11 mm (0.45″)
Resolution C: 0.001 mS/cm, T: 0.001 ⁰C 0.02% FS
ᵃ Standard range
ᵇ Will over-range to 100 mS/cm. Inquire for specifications.
ᶜ Will over-range to 60 ⁰C. Inquire for specifications.
ᵈ Digital auto-ranging
ᵉ When deployed with UV•Xchange™
ᶠ For standard range only. 0.02 m/s for other ranges.
ᵍ For standard range only. 0.5-1.0 m/s for other ranges.
ʰ At 1 m/s flow
Instrument Manual

Sensor Manuals

Biofouling Control Manual

Software Manual

You may also like…