AML-1 with Conductivity & Temperature for Fixed Depth Operations
Water density isn’t static; it fluctuates based on salinity and temperature. For operations at fixed depth deployments, knowing exact density and temperature values can be crucial for equipment performance, safety, and accurate results.
Why choose AML?
AML has over 45 years of history manufacturing conductivity sensors, with thousands delivered to customers worldwide. Our 4 electrode-conductive conductivity cell is a stable, mature technology that has been repeatedly tested against SeaBird CTDs, operating to identical levels of in-field performance. Our conductivity sensors come in two different accuracies: Standard (C:±0.01 mS/cm , T: 0.005 °C) and Scientific (C:0.003 mS/cm5, T: 0.002 °C).
Unique features of the AML solution:
- AML offers the fastest delivery time in the market for CTD or SVP instruments. Our modular approach to sensor-heads allows us to deliver what you need, fast!
- AML offers the largest ecosystem of end-cap sensor heads available in the oceanographic market
- AML’s environmentally friendly bio-fouling control (no TBT!) minimizes in-field maintenance cycles and saves money
- The same biofouling control technology - based on UV light - ensures maximum data accuracy for in-field usage
- Our field-swappable sensor heads increase instrument flexibility; any AML sensor head you own can be installed on any instrument, thus ensuring a ‘fit to purpose’ instrument is always available
- Our field swappable sensor heads create in-field redundancy; sensor-heads can be moved or re deployed to the most critical asset
- Our field swappable sensor heads streamline service, maintenance, and recalibration; only the sensor - not the instrument - needs to travel to a recal centre
Sensor Specs
Conductivity & Temperature
Max Depth | 6000 m |
Range | C: 0-5 or 0-90 mS/cm2 T:-5-45°C |
Precision (±) | C: 0.003 mS/cm T: 0.003 °C |
Accuracy (±) | C:±0.01 mS/cm5 T: ±0.005 °C |
Resolution | C: 0.001 mS/cm T: 0.001 °C |
Response Time | C:25 ms6 T: 100 ms |
Notes | Combined Conductivity & Temperature |
Or
Conductivity & Temperature
High Accuracy
Max Depth | 6000 m |
Range | C: 0-90 mS/cm2 T:-5-45°C |
Precision (±) | C: 0.003 mS/cm T: 0.003 °C |
Accuracy (±) | C:0.003 mS/cm5 T: 0.002 °C |
Resolution | C: 0.001 mS/cm T: 0.001 °C |
Response Time | C:25 ms6 T: 100 ms |
Notes | Combined Conductivity & Temperature |
Probe Specs - learn more about AML-1 here
AML-1 | RTS |
---|---|
Sensor Ports on End Cap | 1 |
Optional External Sensors | No |
Optional Biofouling Control | No |
GPS | No |
Data Communications | RS232, RS485 |
Input Voltage | 8-26 VDC |
Housing Material - (Depth Rating) | Titanium (6000 m) |
Protective Cage Material | No |
Dimensions | 80 x 33 mm |
Weight in Air | 0.3 kg |
Weight in Water | 0.2 kg |